{"product_id":"link-ecu-tcc08-8-channel-egt-to-can-module-101-0388","title":"Link ECU TCC08 8 Channel EGT to CAN Module (101-0388)","description":"\u003cp\u003e\u003cstrong\u003eLink ECU TCC08 8 Channel EGT to CAN Module\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Link ECU\u003cbr\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 101-0388\u003cbr\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe Link 8-Channel EGT to CAN Module\/Amplifier allows up to 8 Type-K thermocouples to be connected to your Link ECU via CAN, providing accurate multi-channel temperature monitoring without using the ECU's analogue inputs.\u003c\/p\u003e\u003cp\u003eIdeal for monitoring individual cylinder exhaust gas temperatures, the TCC08 can also be used for a range of other temperature measurements, including pre- and post-intercooler, turbocharger housing, cylinder head, coolant and oil temperatures. Monitoring individual EGTs allows cylinder-to-cylinder temperature differences to be identified and the data used for tuning, individual cylinder trim and engine protection strategies.\u003c\/p\u003e\u003cp\u003eEach of the 8 Type-K inputs features cold-junction compensation, with temperature data transmitted directly over CAN to the ECU. The module connects through a four-pin DTM connector using Link's standard CAN pinout and is pre-configured for Link ECU integration.\u003c\/p\u003e\u003cp\u003eBuilt-in wireless connectivity allows the TCC08 to be configured and updated from a smartphone or PC, while also providing access to live temperature readings and thermocouple status.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 x cold junction compensated type-K inputs.\u003c\/li\u003e\n\u003cli\u003eFour-pin DTM connector \u0026amp; miniature K-sockets.\u003c\/li\u003e\n\u003cli\u003eCAN Bus connection to ECU (Pre-Configured for Link ECU).\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 0 to 1250degC (32 to 2282degF) with 0.25degC resolution.\u003c\/li\u003e\n\u003cli\u003eDetection of short circuit to ground or if no type-K is connected.\u003c\/li\u003e\n\u003cli\u003eStandard mini k thermocouple connector.\u003c\/li\u003e\n\u003cli\u003eFull configuration and monitoring over wireless.\u003c\/li\u003e\n\u003cli\u003eAdjustable sample frequency up to 100Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSuits\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eAll Link ECUs with CAN Bus support.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1 x CAN EGT Module - custom Link version\u003c\/li\u003e\n\u003cli\u003e1 x DTM4 Mating Connector Kit\u003c\/li\u003e\n\u003cli\u003e2 x Link Stickers\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighlights:\u003c\/strong\u003e DTM 4 CAN Pinout (Supports Links CAN pinout schema and CAN cables range); Pin 1: 12V; Pin 2: Ground; Pin 3: Can Low; Pin 4: Can High; Accuracy: maximum 2% deviation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Options:\u003c\/strong\u003e The module can be configured via wireless:; Can Speed: 125kbps, 250kbps, 500kbps, 1Mbps.; Emulation: Standard, All major aftermarket EGT\/Thermocouple to CAN Modules.; Change of standard Can Bus ID.; Change Big\/Little Endian.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Dimensions:\u003c\/strong\u003e 130mm(L)x35mm(W)x35mm(H); 5.12in(L)x1.38in(W)x1.38in(H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Weight:\u003c\/strong\u003e 115 grams (4.06 ounces)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e Operating Voltage Range: 12V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCLink Calibration Name:\u003c\/strong\u003e To setup a Link TCCXX in PCLink a provided LCS file must be used. First open the CAN Setup dialog, setup your desired Receive User Stream and set the ID to match the CAN ID setup in the TCCXX device.; If using a TCC08, a second Receive User Stream must be setup one CAN ID after the first to receive EGT values 5-8.; Move over to the Streams tab then select the corresponding stream. Select Load Stream then select the correct steam for your device.; Please refer to the Support Section linked below for full set-up instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eNotes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTo setup a Link TCCXX in PCLink a provided LCS file must be used. First open the CAN Setup dialog, setup your desired Receive User Stream and set the ID to match the CAN ID setup in the TCCXX device.\u003c\/li\u003e\n\u003cli\u003eIf using a TCC08, a second Receive User Stream must be setup one CAN ID after the first to receive EGT values 5-8.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Link ECU","offers":[{"title":"Default Title","offer_id":48177596465323,"sku":"LINK 101-0388","price":563.5,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0520\/9319\/0315\/files\/link-ecu-sender-sensors-link-ecu-tcc08-8-channel-egt-to-can-module-101-0388-srcopyright-1261626951.jpg?v=1791496390","url":"https:\/\/stealthride.co.nz\/products\/link-ecu-tcc08-8-channel-egt-to-can-module-101-0388","provider":"Stealth Ride","version":"1.0","type":"link"}